Job Timeline (Ref 15558-20)


All repairs are fixed price at £20 plus postage
Item Returned to Customer


A Timeline of this job can be seen below.
Arrived - 03-Apr-2023
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 15-Apr-2023
Repair Engineer : Martin Smith
LinkedIn Facebook
Please view complete details of this job on the rest of this page (scroll down if on a mobile)

Velux Blind WUR 101 5001 Remote Repair Details

Manufacturer : Velux Blind

Model : WUR 101 5001

Customers Fault Description : The batteries in the remote leaked - we replaced the batteries in both the remote and the blind but we still can't operate the blind. We think it's most likely the remote.

Remote Fixer Repair Response (see below) :

This Velux roller blind remote controller arrived safely from Marlborough and on testing was found not to transmit an IR signal on any button press.

On opening this was found to be due to a corrosion spot in the traces of the print near the IR LED. 

The print was reworked which restored full functionality. 

 


Remote Images

Velux Blind WUR 101 5001 Remote Control - Front Image

Velux Blind WUR 101 5001 Remote Control - Back Image