Job Timeline (Ref 20462-20)
Item Returned to Customer
A Timeline of this job can be seen below.
Arrived - 11-Dec-2023Fault Diagnosed
Remote Repaired
Payment Received
Returned - 03-Jan-2024
Repair Engineer : Martin Smith
LinkedIn Facebook
Please view complete details of this job on the rest of this page (scroll down if on a mobile)
MERTIK MAXITROL GV60 Remote Repair Details
Manufacturer : MERTIK MAXITROL
Model : GV60
Customers Fault Description : Remote control did not activate fire. Replaced batteries in GV60. Noted some corrosion to battery compartment. New batteries did not make GV60 functional. Attempted Reset. No sound from receiver during reset procedure. Assume issue is with receiver.
Remote Fixer Repair Response (see below) :
THis Flavel Curve Gas Fire remote control and receiver arrived safely from Cockermouth and on testing the remote was found to be functioning as normal but the receiver was dead due to badly corroded battery terminals.
The battery block in the receiver was replaced which restored full functionality.
Remote Images