Job Timeline (Ref 21851-20)
Item Returned to Customer
A Timeline of this job can be seen below.
Arrived - 29-May-2024Fault Diagnosed
Remote Repaired
Payment Received
Returned - 12-Jun-2024
Repair Engineer : Martin Smith
LinkedIn Facebook
Please view complete details of this job on the rest of this page (scroll down if on a mobile)
Glow worm Remote Repair Details
Manufacturer : Glow worm
Customers Fault Description : Temperature showing is 30c which means the heating will not function as the temperature will never reach the limit.
Remote Fixer Repair Response (see below) :
This Climapro 2 remote control arrived safely and on testing was confirmed to have an erroneous temperature reading.
This was due to a faulty thermistor, a replacement was fitted which restored full functionality.
Remote Images