Tempure 2000 Remote Repair Details
Manufacturer : Tempure
Model : 2000
Customers Fault Description : ALL BUTTONS ARE WORKING BUT THE HEAD ONLY BUTTON ONLY WORKS OCCASIONLY
This adjustable bed controller arrived safely. On opening the control the button array was found to consist of open topped push switches.
This led to the conclusion that contamination had covered the contacts of the buttons. A meter reading confirmed this as the top left button was found to read a high resistance unless pressed really hard. A switch cleaner was applied to the buttons and full functionality was restored.