Job Timeline (Ref 2491-2883)
Remote Returned to Customer
A Timeline of this job can be seen below.
} ?>
Arrived - 22-Aug-2017
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 23-Aug-2017
e-go Caravan Motor Mover Remote Repair Details
Manufacturer : e-go
Model : Caravan Motor Mover
Customers Fault Description : reverse and side r.h side reverse buttons not working,due to battery leak.
This caravan motor mover controller arrived safely and on opening was found to have badly corroded button pads on the PCB caused by a battery leakage (see image), the contamination was removed and the print reworked around the buttons and full functionality was restored.