Job Timeline (Ref 2579-2987)
Remote Returned to Customer
A Timeline of this job can be seen below.
} ?>
Arrived - 08-Oct-2017
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 12-Oct-2017
enduro quartocar Remote Repair Details
Manufacturer : enduro
Model : quartocar
Customers Fault Description : does not connect with main unit, before that button at 7 o'clock reverse turn anti clock wise only worked half
This Enduro controller arrived safely and on testing was found not to be sending a RF signal.
On opening there was 2 issues found, the first was that there was contamination over much of the button array and the 2nd was that the rf crystal was away from the board due to a poor solder joint.
The PCB was given an alcohol bath and the crystal resoldered. Full functionality was restored.
Remote Images