Job Timeline (Ref 2689-3111)
Remote Returned to Customer
A Timeline of this job can be seen below.
} ?>
Arrived - 01-Nov-2017
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 08-Nov-2017
Dia Dragon Remote Repair Details
Manufacturer : Dia
Model : Dragon
Customers Fault Description : Wire unattached from body, lcd screen broken, screws missing, please repair if there are any reasonable extra costs please continue
This Spa massage chair controller arrived safely and on inspection the back screws were missing, the cable was loose with a broken lead and the display was cracked.
The display cannot be replaced due to lack of availability of spares, the customer was contacted and it was established that the control works without the display, therefore the repair was carried out to the cable and was soldered directly into the PCB. The back was then glued back into place.