Job Timeline (Ref 2738-3166)
Remote Returned to Customer
A Timeline of this job can be seen below.
} ?>
Arrived - 16-Nov-2017
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 23-Nov-2017
Triton Remote Repair Details
Manufacturer : Triton
Customers Fault Description : Will not turn the drier on.
This body dryer control arrived safely and on inspection all buttons were suffering from cracks in the facia. On testing THE CONTROL was found to be transmitting on the lower 4 buttons but had no response from the top 2 buttons, when the facia was peeled off the problem was clear, there was corrosion on the button contacts due to moisture contaminstion.
The print was reworked and the facia glued back on and full functionality was restored. A plastic sheeting was also fitted over the facia to give prevent the buttons from detaching altogether.