Job Timeline (Ref 4359-5082)
Remote Returned to Customer
A Timeline of this job can be seen below.
} ?>
Arrived - 18-Jun-2019
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 20-Jun-2019
Repair Engineer : Martin Smith
LinkedIn
Facebook
ENDURO PURPLELINE Remote Repair Details
Manufacturer : ENDURO PURPLELINE
Customers Fault Description : RED LIGHT DOES NOT COME ON WHEN START BUTTON IS PRESSED TWICE.
SOMETIMES THE REMOTE CONTROLS THE MOTORS ANYWAY.
IT SEEMS THE CONTROLLER DOES NOT LATCH ON. MOST TIMES THE RELAYS IN THE CONTROL BOX IN THE CARAVAN SOUND "CLICK CLICK CLUNK" AND IT DOESN'T WORK.
JUST "CLICK CLICK "DOES WORK.
WHEN IT DOES WORK THE MOTORS CAN EACH BE MADE TO MOVE CLOCK AND ANTICLOCKWISE
This caravan motor mover control arrived safely and on testing was found to not be powering on as normal operation.
When opened the first issue was a faulty LED, this was replaced which restored partial functionality. This item was found to have a very strange issue whereby each button was only soldered into position by only 3 of the 4 solder points on every button! If this is the first time this has been maintained then this is a manufacturer error.
All buttons were replaced and soldered completely which restored full functionality.
Remote Images