Job Timeline (Ref 4583-5351)
Remote Returned to Customer
A Timeline of this job can be seen below.
} ?>
Arrived - 22-Aug-2019
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 29-Aug-2019
Repair Engineer : Martin Smith
LinkedIn
Facebook
Triton Body Dryer Remote Repair Details
Manufacturer : Triton
Model : Body Dryer
Customers Fault Description : Button worn and unreliable alson battery cover loose/pins snapped -- taped up but tghis ok
This body dryer controller arrived safely and on inspection the battery cover was held on with tape, this cannot be replaced and tape will be needed to hold the cover on.
When testing the up button was not responding, the facia was peeled back and there was a corrosion point in the print which was causing an open circuit.
The print was reworked which restored functionality. Replacement button caps were fitted under the facia.