Job Timeline (Ref 2596-3003)
Remote Returned to Customer
A Timeline of this job can be seen below.
} ?>
Arrived - 03-Oct-2017
Fault Diagnosed
Remote Repaired
Payment Received
Returned - 06-Oct-2017
TRUMA Mover SE Remote Repair Details
Manufacturer : TRUMA
Model : Mover SE
Customers Fault Description : The unit does not switch on reliably but can usually be persuaded to work by shaking or tapping. Loose connection? There is also a rattling sound when the unit is shaken.Sooner or later it will let me down completely. The on /off switch does not move easily so needs to slid using a key but this is not in itself a problem
This caravan mover control arrived safely and was indeed found to be "rattling" and not responding porerply from the power switch.
This is a common problem caused by a retaining pin breaking and allowing the PCB to move freely around internally.
The control was cut open and the board hot melt glued firmly into position. Full functionality was restored.