Altus Roller Brake Tester Remote Repair Details

Manufacturer : Altus

Model : Roller Brake Tester

Customers Fault Description : Top three buttons (Left/Both/Right) do not work.

Remote Fixer Repair Response (see below) :

This brake tester control arrived safely adn on testing was confirmed to have faulty buttons.  The facia is cracked around various buttons, this is allowing moisture / contamination within the facia causing contamination within the button pads.  The facia was peeled apart and cleaned of all contaminants, also the main IC had started to "creep" from its socket, this was reseated and full functionality was restored.

Please note that this facias are not available as spares and therefore great care must be taken to try to prevent contaminants entering the button array (maybe inserting the control inside a clear sealed bag when in use, eliminating third party contaminants from entering the controls array).

A clone was supplied as requested