Job Timeline (Ref 6622-7781)
Remote Diagnosed
A Timeline of this job can be seen below.
} ?>
Arrived - 05-Oct-2020
Fault Diagnosed
Repair Engineer : Martin Smith
LinkedIn
Facebook
Mertik Maxitrol G30 - Zrrs Remote Repair Details
Manufacturer : Mertik Maxitrol
Model : G30 - Zrrs
Customers Fault Description : Remote sometimes close gas valve but will not open valve
Remote Fixer Repair Response (see below) :
This fireplace control and receiver arrived safely and on inspection both the remote and receiver had suffered from a battery leak / corrosion damage (see images)
The remote would intermittently transmit, this was rectified by replacing hte badly corroded cable. The battery block and crystals were replaced in the receiver which restored functionality but sadly this failed after a few hours. When the receiver is heated with a soldering iron it would sprint to life for a short while, because of this a diagnosis is not possible. This has deemed a repair non possible.
Replacements can be found here!
These items were scrapped as per the customers telephone request 13th Oct 2020
Remote Images